top of page

Promoting digitalization of cleaning cycles and inspection work

TK-2000J

TK-2000J Camera

Measuring of accumulated dirt and debris depth in ducts

Main application areas

​- Kitchen ducts, restaurant exhaust ducts, ventilation ducts

Main functions

​- Measuring dirt and debris depth using laser irradiation  

- Remote monitoring of interior areas with image capturing

- Temperature measurement adapted to high temperatures

- Alert function triggered by specified temperatures

230315_AMOS_010_edited.jpg

The process to develop the TK-2000J

1  Development was abandoned due to seasonal variations in measurement accuracy caused by changes in the speed of sound depending on temperature and humidity

2  Measuring the depth of accumulated dirt and debris proved difficult with current image processing technology

​3  Development was focused on measurements using light, but because the measurements are performed in an enclosed space, diffuse reflection made measurements impossible

March 2022

A centroid triangulation method is established using diffuse reflection of light

October 2021

T-SENSOR T-1000J for remote monitoring is launched

January 2022

Development of the heat-resistant, chemical-resistant, Fire Service Act-compliant multi-sensor TK-2000J is started

​Development specifications: Equipped with duct monitoring and depth sensing functions

TK-2000J visual photo
023_edited.jpg
T-SENSOR logo

​Capable of measuring the dirt and debris depth in ducts

By measuring the depth of dirt and debris inside the duct, oil films and other buildup that can cause fires can be cleaned at the right time.

The sensor is installed in the duct.

Ensuring a distance

of 100 mm

In the case of kitchen exhaust ducts, the TK-2000J meets the provision set out in the Fire Prevention Ordinance (No. 65) that states that there must not be any flammable materials within 100 mm of the duct surface.

Laser

​Measurable up to 150°C

Can be used for ducts in high-temperature environments such as restaurants, etc., as the TK-2000J uses a thermocouple to measure temperatures.

Duct Fire
重心点三角測量法イラストグレー(En).png

Centroid triangulation method

1.A reflector is installed to ensure a separation distance of 100 mm   between the laser source and the duct surface, and the laser is  irradiated at a fixed angle.

2. Multiple images are taken to improve measurement accuracy by              calculating the coordinates of the bright spots and centroid.

3. The accumulation of dirt and debris in the duct causes the centroid to   shift, allowing the depth to be measured.

Depth measurement method

Gallery

Model name

SPEC

TK-2000J

Unit size

360.55mm

Sensor pipe

254.55mm

Compatible duct dimensions

 

200 - 800 mm

Laser for measurement

Laser Class 1 or so

Allowable operating temperature

When the camera is not in use: 0–150°C, 90% RH or less

When the camera is in use: 0–50°C, 90% RH or less

Waterproof/dustproof structure

Waterproof and dustproof construction

Resolution : SXGA (1280 x 1024)

Imaging function

Imaging range: Distance from subject of 40 cm or more

Imaging time: 20 sec

Rated voltage

DC-24V

Current consumption

Max 0.4A

Electrostatic discharge

 

Contact discharge of 4 kV and air discharge of 8 kV,

per IEC61000-4-2

Communication module

BLE/Wi-Fi Combo Module

Outdoor use

Outside air temperature of 50°C or less

Country of use

JAPAN

Various standards
Bluetooth SIG certified / Wi-Fi certified / Technical conformity certification / RoHS compliant,REACH regulation