Promoting digitalization of cleaning cycles and inspection work
TK-2000J

Measuring of accumulated dirt and debris depth in ducts
Main application areas
- Kitchen ducts, restaurant exhaust ducts, ventilation ducts
Main functions
- Measuring dirt and debris depth using laser irradiation
- Remote monitoring of interior areas with image capturing
- Temperature measurement adapted to high temperatures
- Alert function triggered by specified temperatures

The process to develop the TK-2000J
1 Development was abandoned due to seasonal variations in measurement accuracy caused by changes in the speed of sound depending on temperature and humidity
2 Measuring the depth of accumulated dirt and debris proved difficult with current image processing technology
3 Development was focused on measurements using light, but because the measurements are performed in an enclosed space, diffuse reflection made measurements impossible
March 2022
A centroid triangulation method is established using diffuse reflection of light
October 2021
T-SENSOR T-1000J for remote monitoring is launched
January 2022
Development of the heat-resistant, chemical-resistant, Fire Service Act-compliant multi-sensor TK-2000J is started
Development specifications: Equipped with duct monitoring and depth sensing functions


Capable of measuring the dirt and debris depth in ducts
By measuring the depth of dirt and debris inside the duct, oil films and other buildup that can cause fires can be cleaned at the right time.

Ensuring a distance
of 100 mm
In the case of kitchen exhaust ducts, the TK-2000J meets the provision set out in the Fire Prevention Ordinance (No. 65) that states that there must not be any flammable materials within 100 mm of the duct surface.

Measurable up to 150°C
Can be used for ducts in high-temperature environments such as restaurants, etc., as the TK-2000J uses a thermocouple to measure temperatures.


Centroid triangulation method
1.A reflector is installed to ensure a separation distance of 100 mm between the laser source and the duct surface, and the laser is irradiated at a fixed angle.
2. Multiple images are taken to improve measurement accuracy by calculating the coordinates of the bright spots and centroid.
3. The accumulation of dirt and debris in the duct causes the centroid to shift, allowing the depth to be measured.
Depth measurement method
Gallery
Model name
SPEC
TK-2000J
Unit size
360.55mm
Sensor pipe
254.55mm
Compatible duct dimensions
200 - 800 mm
Laser for measurement
Laser Class 1 or so
Allowable operating temperature
When the camera is not in use: 0–150°C, 90% RH or less
When the camera is in use: 0–50°C, 90% RH or less
Waterproof/dustproof structure
Waterproof and dustproof construction
Resolution : SXGA (1280 x 1024)
Imaging function
Imaging range: Distance from subject of 40 cm or more
Imaging time: 20 sec
Rated voltage
DC-24V
Current consumption
Max 0.4A
Electrostatic discharge
Contact discharge of 4 kV and air discharge of 8 kV,
per IEC61000-4-2
Communication module
BLE/Wi-Fi Combo Module
Outdoor use
Outside air temperature of 50°C or less
Country of use
JAPAN
Various standards
Bluetooth SIG certified / Wi-Fi certified / Technical conformity certification / RoHS compliant,REACH regulation